Reefer and cooling units · AP-7

Reefer and cooling units on the AP-7, Figueres

The Figueres stretch packs exits 5 and 6, the N-II link into town and the industrial estate, plus the start of the express road towards Roses and the Costa Brava, into a short but busy section. Local traffic mixes with international transit, and a reduced-speed curve works brakes and suspension hard.

Reefer and cooling units

When the fridge stops with meat, fish or pharmaceuticals inside, the clock is running against you. We handle unit start failures, belts and pulleys, temperature sensors, pressure switches and gas loss, plus Thermo King and Carrier Transicold alarm codes. These jobs go to the front of the queue, because the load does not wait.

When a refrigeration unit fails it is not just a truck that stops: it is an entire load. Most thermal breakdowns on the road are electrical (connectors, blower motors, auxiliary batteries) or refrigerant-side (slow leaks in stone-pelted condensers), and both families allow a good share of roadside repair.

Before opening anything, read the unit display: Carrier and Thermo King alarm codes say a lot (low voltage, high discharge pressure, start failure). With the code in hand the intervention narrows and saves half an hour of blind testing.

What never to do

  • Do not open the box to check the load
  • Do not reset the unit repeatedly — it wipes the fault history
  • Do not wait until the cold chain is already broken to call
  • Temperature alarm. The display reports deviation from setpoint: act before the load climbs out of chain.

How it works

Read the alarm code, check supply voltages and earths, inspect condenser and evaporator visually. Electrical faults get repaired from portable stock; refrigerant leaks are traced with an electronic detector and recharged with exactly the gas and charge stated on the unit plate, leaving a temperature log for the receiver.

  1. 1
    Read the alarm

    Display code plus the unit's stored temperature log.

  2. 2
    Electrical circuit first

    Voltages, connectors and blowers: some 70% of stoppages.

  3. 3
    Refrigerant circuit

    Electronic leak trace, repair, recharge to plate specification.

  4. 4
    Temperature report

    Deliverable log proving the cold chain held.

Service

24 h reefer callout. Diagnosis + electrical or leak repair + temperature report.

Blow the condenser clean with compressed air weekly in hot weather and check the unit's belt tensioner: a dirty condenser spikes pressures and kills expensive compressors.

AP-7 · Figueres

Half-way along the corridor, this stretch merges the flows coming off the border with those climbing from Barcelona: braking, overtaking and lane changes without pause.

Figueres entry, industrial zone and N-II access. Mandatory passage toward Roses/Costa Brava.

AP-7
5 – 6
Figueres
Cataluña
24/7
24 hours · 365 days

Questions about this stretch

Most often it's the hard shoulder between exits 5 and 6, the N-II junction or inside the estate itself. If you can roll to a safe lay-by, say so on the call: that always beats the shoulder.
Yes, Figueres coverage includes the start of that road. Send us the location and on the call we confirm whether we take it or coordinate closer assistance.
On short climbs and stop-start queues we regularly see overheating and brake wear from constant use. We check the whole circuit on site before you continue.

Other services at Figueres

Contact

Tell us what the truck is doing

If the truck is stopped right now, call. The form is for quotes, fleet contracts and anything that can wait.

24 h telephone
+34 911 677 405
Hours
24 hours · 365 days
Operating base
La Jonquera, Girona (AP-7)

Request assistance or a quote

We reply the same working day.

For a breakdown in progress, phone us — it is faster.

+34 911 677 405 WhatsApp